Powered by Spearhead Software Labs Joomla Facebook Like Button

TR 240 TR 60 with observation window

TR 450

Electrical rotating device as additional equipment

TR 1050 with double door

TR 60 - TR 1050

With their maximum working temperature of up to 300 °C and forced air circulation, the ovens achieve a perfect temperature uniformity which is much better than in ovens of most competitors. They can be used for various applications such as e.g. drying, sterilizing or warm storing. Ample warehousing of standard models provides for short delivery times.

  • Tmax 300 °C
  • Working temperature range: + 5 °C above room temperature up to 300 °C
  • Ovens TR 60 - TR 240 designed as tabletop models
  • Ovens TR 450 and TR 1050 designed as floor standing models
  • Horizontal, forced air circulation results in temperature uniformity better than +/- 5 °C
  • Stainless steel chamber, alloy 304 (AISI)/(DIN material no. 1.4301), rust-resistant and easy to clean
  • Large handle to open and close the door
  • Charging in multiple layers possible using removeable grids (number of removeable grids included, see table to the right)
  • Large, wide-opening swing door, hinged on the right with quick release for models TR 60 - TR 450
  • Double swing door with quick release for TR 1050
  • TR 1050 equipped transport rollers
  • Infinitely adjustable exhaust at the rear wall with operation from the front
  • PID microprocessor control with self-diagnosis system
  • Solid state relays provide for low­noise operation
  • Defined application within the constraints of the operating instructions

Additional equipment

  • Over-temperature limiter with adjustable cutout temperature for thermal protection class 2 in accordance with EN 60519-2 as temperature limiter to protect the oven and load
  • Infinitely adjustable fan speed of the air circulation fan
  • Window for charge observing
  • Further removeable grids with rails
  • Side inlet
  • Stainless steel collecting pan to protect the furnace chamber
  • Safety technology according to EN 1539 for charges containing liquid solvents (TRS) up to model TRS 240, achievable temperature uniformity +/- 8 °C
  • Transport costors for model TR 450
  • Various modifications available for individual needs
  • Upgrading available to meet the quality requirements of AMS 2750 E or FDA
  • Process control and documentation with Controltherm MV software package
ModelTmaxInner dimensions in mmVolumeOuter dimensions in mmConnectedElectricalWeightGrids in-GridsMax.
 °Cwdhin lWDHload kW2connection*in kgcludedmax.total load1
TR 60 300 450 380 350 60 700 650 690 3.1 1-phase 90 1 4 120
TRS 60 260 450 360 350 57 700 680 690 6.3 3-phase 92 1 4 120
TR 120 300 650 380 500 120 900 650 840 3.1 1-phase 120 2 7 150
TRS 120 260 650 360 500 117 900 680 840 6.3 3-phase 122 2 7 150
TR 240 300 750 550 600 240 1000 820 940 3.1 1-phase 165 2 8 150
TRS 240 260 750 530 600 235 1000 850 940 6.3 3-phase 167 2 8 150
TR 450 300 750 550 1100 450 1000 820 1440 6.3 3-phase 235 3 15 180
TR 1050 300 1200 630 1400 1050 1470 955 1920 9.3 3-phase 450 4 14 250
1Max load per layer 30 kg *Please see page 60 for more information about supply voltage
2If EN 1539 is ordered connected load will increase
 

High-Temperature Ovens, Air Circulation Furnaces

 
NA 250/45 NA 120/45  

N 15/65HA as table-top model

N 15/65HA, NA 30/45 - N 500/85HA

These chamber furnaces with air circulation are characterized by their extremely high temperature uniformity. Hence, they are especially suitable for processes such as cooling, crystalizing, preheating, curing, but also for numerous processes in tool making. Due to the modular concept, the air circulation furnaces can be adjusted to the process requirements by adding suitable equipment.

  • Tmax 450 °C, 650 °C, or 850 °C
  • Horizontal air circulation
  • Swing door hinged on the right
  • Temperature uniformity up to +/- 5 °C according to DIN 17052-1 (model N 15/65 HA up to +/- 7 °C)
  • Optimum air flow and temperature uniformity through high circulation rates
  • One shelf and rails for two additional shelves included (N 15/65 HA without removable tray)
  • Stainless steel air-baffles in the furnace for optimum air circulation
  • Base frame included in the delivery, N 15/65 HA designed as table-top model
  • Air inlet and exhaust air flaps as additional equipment for using as drying oven
  • Defined application within the constraints of the operating instructions
ModelTmaxInner dimensions in mmVolumeOuter dimensions in mmConnectedElectricalWeight
 °Cwdhin lWDHload kWconnection*in kg
NA 30/45 450 290 420 260 30 1040 1290 1385 3.6 1-phase 195
NA 60/45 450 350 500 350 60 1100 1370 1475 6.6 3-phase 240
NA 120/45 450 450 600 450 120 1200 1470 1575 9.8 3-phase 310
NA 250/45 450 600 750 600 250 1350 1650 1725 12.8 3-phase 610
NA 500/45 450 750 1000 750 500 1500 1850 1800 18.8 3-phase 1030
                       
N 15/65 HA1 650 295 340 170 15 470 845 460 2.7 1-phase 55
N 30/65 HA 650 290 420 260 30 607 + 255 1175 1315 6.0 3-phase2 195
N 60/65 HA 650 350 500 350 60 667 + 255 1250 1400 9.6 3-phase 240
N 120/65 HA 650 450 600 450 120 767 + 255 1350 1500 13.6 3-phase 310
N 250/65 HA 650 600 750 600 250 1002 + 255 1636 1860 21.0 3-phase 610
N 500/65 HA 650 750 1000 750 500 1152 + 255 1886 2010 31.0 3-phase 1030
                       
N 30/85 HA 850 290 420 260 30 607 + 255 1175 1315 6.0 3-phase2 195
N 60/85 HA 850 350 500 350 60 667 + 255 1250 1400 9.6 3-phase 240
N 120/85 HA 850 450 600 450 120 767 + 255 1350 1500 13.6 3-phase 310
N 250/85 HA 850 600 750 600 250 1002 + 255 1636 1860 21.0 3-phase 610
N 500/85 HA 850 750 1000 750 500 1152 + 255 1886 2010 31.0 3-phase 1030
1Table-top model*Please see page 60 for more information about supply voltage
2Heating only beetween two phases